SME100 Reset Mode Summary
Mode Activation Result Purpose and Notes
Factory Firmware
1 Hold in the recessed Reset
button while applying power
to the unit.
The SME100 reverts to the factory
default firmware for a single power
cycle.
Booting to this mode twice in a row
deletes all user files; settings (such as
drivers, adjustments, and IP settings)
are set to factory default.
Use mode 1 to revert to
the factory default firmware
for a single power cycle if
incompatibility issues arise
with user-loaded firmware.
Reset All IP Settings
4 Hold in the Reset button for
about 6 seconds until the
Power LED blinks twice (once
at 3 seconds, again at 6
seconds). Then, release and
press Reset again within
1 second*.
Mode 4:
• Enables ARP capability.
• Sets the IP address back to
factory default (192.168.254.254).
• Sets the subnet mask address
back to the factory default
(255.255.0.0).
• Sets the gateway IP address to
the factory default (0.0.0.0).
• Sets port mapping back to factory
default.
• Turns DHCP off.
• The Reset LED on the rear panel
of the unit flashes four times in
succession.
Mode 4 is used to set
IP address information using
ARP and the MAC address.
A "Resetting IP Settings"
message appears on the
LCD display.
Reset to Factory Defaults
5 Hold in the Reset button for
about 9 seconds until the
Power LED blinks three times
(once at 3 seconds, again
at 6 seconds, again at 9
seconds). Then, release and
press Reset again within
1 second*.
Mode 5:
Performs a complete reset to factory
defaults (except the firmware).
• Does everything mode 4 does.
• Clears port configurations.
• Resets all IP options.
• Clears all user settings.
• Clears all files from the unit.
• The Reset LED on the rear panel
of the unit flashes four times in
succession.
Mode 5 is useful when wanting
to start over with configuration
and uploading, and also to
replace events.
"Resetting SME100" appears
on the LCD display.
NOTE:
*
= For modes 4 and 5, nothing happens if the momentary press does not occur within 1 second.
SME100 • Panels and Cabling 16