68-959-01 Rev. F07 12System Control PanelsSCP 226 and SCP 104 SeriesUser Guide
312OUTPUTINPUTSMLS 103 VL RABLRL RLR123LR4AUX/MIXMONOAUDIO INPUTSOUTCONTROL/POWER12V .5A MAXBASSLEVELTREBLEMINI POWER AMPLIFIERMPA 152STEREODUA
Installation and OperationThis section describes the front and rear panel features of the six SCP 104/226 models and provides procedures for installin
Installation OverviewATTENTION: Installation and service must be performed by authorized personnel only.To install and set up an SCP control panel:1.
Fig_Replacing button label2 3 TEXT Separate the two-piece button here atthe corner.Pry the two pieces apart. Diffuser Plunger Base Button Label Clear
Rear Panel Features and Connections1 ON 2 3 4 J1 1 2 4 ABCDEABCDEFigure 4. SCP 104 Rear Panel1 ON 2 3 4 J1 1 3 4 ABCDEABCDE2 Figure
NOTE: The SCP must be in standalone mode for communication via SIS commands (see the “Remote Communication” section, beginning on page 31). • Switch
d Serial port — Use this female 3-pole 3.5 mm captive screw connector to connect the SCP to the serial (RS-232) port on your computer. Through this co
1ON234J1J4J6SW12SCP 226 Rotated Rear PanelTo Computer orControl SystemRS-232 Port9-pin HDConnectorGround ReceiveTransmitTx3Transmit (Tx)Receive (Rx)2G
Wiring the Power Connector (Optional)If powering the SCP using a 12 V, 1 A external power supply (instead of powering via an MLC or System 5 IP), conn
Connecting to the MLC 104/226, the System 5 IP, and Control Modules The diagrams on the following pages illustrate how to connect the SCP to the MLC 1
Precautions This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with
SCP 226 to MLC 226 IPSCP 226200' (61 m) max.to Last DeviceEBASCP Communication+12 VDCGround ( ) & Drain WireMLC 226 IPRear PanelExtron CTLP
SCP 226 to MLC 226 IP with IRCM-DV+ control modulesSCP 2263-pole ConnectorSCP 2263-pole ConnectorCBACBAExtron CTLP Cable Color Code:200' (61 m) m
SCP to system switcherSCP 104Extron CTLP Cable Color Code:200' (61 m) max.to Last DeviceIRCM-DV+Control ModuleAddress 1 and 2ECBASCP Communicatio
Two SCP 226s to system switcher and two control modulesFigure 15. Connecting Two SCP 26 Control Panels to a System Switcher and Two Control Modu
SCP and System 5 IP Button FunctionsWhen an SCP is connected to a System 5 IP switcher, buttons on the SCP initiate functions that are also controlled
Mounting the SCP After the system has been cabled and tested, the control panel can be mounted to the wall or furniture. Mounting OptionsYou can mount
Fig_Mounting SCP 104_2-gang2-gangWall BoxExtronSCP 104CONFIG PROJECTOR VOLUME 1 2 3 4 ON OFF Figure 18. Mounting an SCP 104 in a Tw
Front Panel FeaturesThe controls on the SCP 104/226 replicate the programmed MLC 104/226 buttons and controls, and most of the System 5 IP front panel
SCP 104PROJECTORVOLUMEONOFF12341367777 Figure 20. SCP 104 Front PanelSCP 104 AAP43617777Figure 21. SCP 104 AAP Front PanelSCP 104 and SCP 226 • Inst
Figure 22. SCP 226 Front PanelFigure 23. SCP 226 AAP Front PanelVOLUME SCP 226 IR PROJECTOR Extron 1 2 3 4 5 6 ON OFF 1326777 75Extron PROJECTOR 1
安全须知 • 中文这个符号提示用户该设备用户手册中有重要的操作和维护说明。这个符号警告用户该设备机壳内有暴露的危险电压,有触电危险。注意阅读说明书 • 用户使用该设备前必须阅读并理解所有安全和使用说明。保存说明书 • 用户应保存安全说明书以备将来使用。遵守警告 • 用户应遵守产品和用户指南上的所有安
Extron PROJECTOR 1 2 3 4 5 6 VOLUME IR ON OFF SCP 226 273777156Figure 24. SCP 226 L Front Panela On and Off buttons — Press these buttons to turn the
d AAP mounting spaces (SCP AAP models only) — Mount up to four single space AAPs or control modules (IRCMs or RCMs) here.e IR signal pickup sensor (SC
f Volume knob and indicator LEDs — Turn this knob to adjust the volume on the input that is currently selected. The five LEDs light incrementally, bot
VOLUMESCP 226IRPROJECTORExtron123456ONOFFTo reset, press these buttons simultaneously while applying power.Figure 28. Resetting the SCP 226 to Factor
3. On the Download Center screen, click Software on the left sidebar menu. The Download Center Control Software screen appears.4. On the software li
8. Start the Firmware Loader program by clicking the Firmware Loader icon on your computer Start menu. The Firmware Loader Add Device screen appears.
Figure 33. Open Window for Firmware12. In the Open window, locate and double-click on the firmware filename (it has a .bin extension).NOTE: The firmwa
Remote CommunicationThis section discusses use of SIS commands via RS-232 communication to monitor and get information from the SCP. It contains lists
SCP-initiated MessagesAt power-up, the following SCP-initiated message appears:(c) Copyright 20nn, Extron Electronics, SCP 104 [or 226], Vn.nnNOTE: T
Using the Command and Response TablesThe command and response tables on the following pages list valid command ASCII codes, the SCP responses to the h
Conventions Used in this GuideNotifications the following are used:WARNING: Risk of physical injury. A warning indicates a situation that has the pot
CommandASCII Command(Host to SCP)Hex(Host to SCP)Response(SCP to Host)Additional DescriptionInformation RequestsQuery firmware versionq 71X! ]Show curr
CommandASCII Command(Host to SCP)Hex(Host to SCP)Response(SCP to Host)Additional DescriptionInformation Requests (continued)Request control module and
CommandASCII Command(Host to SCP)Hex(Host to SCP)Response(SCP to Host)Additional DescriptionUpload FirmwareUpload firmwareE Upload }Go ]Upl ]When you r
Special Function SIS CommandsThe syntax for setting a special function for an SCP 104/226 is X? * Y? * __ #, where X? is the value of the action to be
CommandASCII Command(Host to SCP)Response(SCP to Host)X? and Y? Values and Additional DescriptionsSwitch ResponsesButton press on front panel or rem
CommandASCII Command(Host to SCP)Response(SCP to Host)X? and Y? Values and Additional DescriptionsFront Panel Button LED ControlFPC lamp controlX? *
Using the Switch and Button TableSwitches are assigned to specific buttons on the SCP, any attached remote control module (IRCM or RCM), or the IR 402
Front panel switch locationsVOLUME SCP 226 IR PROJECTOR Extron 1 2 3 4 5 6 ON OFF 1259 101112 131467Figure 35. Switch Locations on the SCP 226Fig_Sw
IR 402 switch locations21412112373651111091251101161182412012212411311211411911711525108IR 402See the SCP 104/226front panel.9-22Figure 37. Switch Nu
uFig_Button and Switch numberingSCREEN POSITIONDOWN UPSTOPDVD & VCR CONTROLPLAYNEXT/FWDPAUSE STOPTUNERTxPREV/REWENTERTITLE MENUTV/VCRDVDVCRDVD &am
ContentsIntroduction ...1About this Guide ... 1About the SCP 104 and SCP 226 System C
Switch and Button TableSwitch Button Switch Button Switch ButtonCM3_2CM3_3CM3_4CM3_5CM3_6CM3_7CM3_8CM3_9CM3_10CM3_11CM3_12CM3_13CM3_14CM3_15CM3_16CM3_
Reference InformationThis section contains reference information for all SCP 104 and SCP 226 models. Topics include: • Part Numbers • Cutout Templates
Recommended CablesCable Types Part NumbersCTLP/1000 Plenum 1000' (300 m) spool 22-119-03CTL/1000 Non-Plenum 1000' (300 m) spool 22-148-03A
Cutout TemplatesThis section contains the following cutout templates: • SCP 104 Cutout Template • SCP 104 AAP Cutout Template • SCP 226 Cutout Templat
SCP 104 AAP Cutout TemplateSCP 104 AAPCut-Out Template for Extron'sTEMPLATE IS NOT FULL SIZE.4.50" (11.43 cm)To install SCP 104directly into
SCP 226 Cutout TemplateTo install SCP 226directly into furniture,cut along this line.Top Panel2.81"(7.13 cm)5.24"(13.3 cm)SURFACE CUT-OUT AR
SCP 226 AAP Cutout Template10.13"(25.65 cm)SCP 226 AAPCut-Out Template for Extron'sTEMPLATE IS NOT FULL SIZE.4.50" (11.43 cm)To install
SCP 226 L Cutout TemplateSCP 226 LCut-Out Template for Extron's6.50"(16.51 cm)TEMPLATE IS NOT FULL SIZE.To install SCP 226directly into furn
52 SCP 104 and SCP 226 • Reference Information
WarrantyExtron WarrantyExtron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date
SCP 104 and SCP 226 • Contentsvi
Extron USA Headquarters +800.633.9876 (Inside USA/Canada Only)Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517
IntroductionThis section gives an overview of the SCP 104 and SCP 226 System Control Panels and describes their features. Topics include: • About this
The MediaLink controllers and the System 5 IP each support up to two of the SCP 104/226, the SCP 226 L, or the SCP 104/226 AAP models. The MLC 104/226
Application DiagramsThe following illustrations show examples of how the SCP can be connected. 100-240V 0.2A50-60Hz+_LEFT+RIGHT_BASC4C3CC12BAECD56T
Komentáře k této Příručce