Strany 1 - User Guide

68-2028-01 Rev. B10 13TLP 710MV and TLP 710TVUser GuideTouchLink®TouchLink Touchpanel Control Systems

Strany 2 - Safety Instructions

Panel FeaturesThis section describes:• TLP 710MV Front Panel Features and Operations• TLP 710MV Rear Panel Features and Connections• TLP 710TV Fron

Strany 3 - FCC Class A Notice

f Connection status LED — is unlit during normal operation. Blinks red if the connection to the IP Link controller is lost.g Bezel — removable with

Strany 4 - Specifications Availability

TLP 710MV Rear Panel Features and ConnectionsExtron13161415Figure 5. TLP 710MV Rear Panel Featuresm Power connector — Connect the 2-pole, 3.5 mm cap

Strany 5 - Contents

ATTENTION: • Always use a power supply supplied by or specified by Extron. Use of an unauthorized power supply voids all regulatory compliance certific

Strany 6

Extron recommends using a Power over Ethernet (PoE) power supply. Use a straight-through Ethernet cable to connect the power supply to a switch or rou

Strany 7 - Introduction

TLP 710TV Front Panel Features and OperationsExtronabcdefdFigure 8. TLP 710TV Front Panel Featuresa Motion sensor — is capped with a small Fresnel

Strany 8 - TLP 710MV

TLP 710TV Rear Panel Features and ConnectionsThe TLP 710TV has a stand that allows it to be placed on desktop. The stand can be removed to VESA mount

Strany 9 - Other Hardware

k Power connector — Connect the 2-pole, 3.5 mm captive screw connector from the 12 VDC, 1.0 A power supply (not provided) to the power supply socket

Strany 10 - Panel Features

n MTP input — A twisted pair cable, terminated with an RJ-45 connector, provides video and audio input from an Extron MTP transmitter. The MTP port i

Strany 11 - Reset Buttons and LED

NOTE: The twisted pair cable providing the MTP (Figure 9, n) and network LAN (Figure 9, o) connections should be secured together and to both the bac

Strany 12 - (5 mm) Max

Safety Instructions • EnglishWARNING: This symbol, D, when used on the product, is intended to alert the user of the presence of uninsulated dangerou

Strany 13 - RJ-45 Port

Initial CalibrationThis section describes:• Accessing the Internal On-screen Menus• Main Screen• Volume Screen• Time Screen• Network Screen• Vid

Strany 14 - PWR LAN-OUT LAN-IN

The Sleep timer buttons determine how long the panel will be inactive before it enters Sleep mode, when the screen goes dark to save power. The time c

Strany 15

Time ScreenExitDown UpMonth: 06Down UpHours: 13Down UpDay: 06Down UpMinutes: 32Down UpYear: 2011MainVolumeTimeNetworkVideoFigure 15. Time ScreenUse th

Strany 16

Video ScreenExitMainVolumeTimeNetworkVideoDown UpContrast: 064Down UpColor: 064Down UpBrightness: 128Down UpTint: 128Figure 17. Video ScreenThe small

Strany 17

Configuration SoftwareThis section of the user guide provides information about:• The Configuration Software• Installing the Software• Using the Tou

Strany 18

If required, locate the Global Configurator program on the disc or website and install that also. By default, the Installer program creates and places

Strany 19

2. Click the Configuration tab and then click System Settings in the menu in the left sidebar. This page allows the user to modify the IP settings an

Strany 20 - Initial Calibration

4. To upgrade the firmware, select Firmware Upgrade. For more detailed instructions, see Updating Firmware from a Web Browser on page23.5. Click the

Strany 21 - Volume Screen

3. Also from the Extron Download page, download the firmware for the TouchLink panel. Click the Firmware link on the left sidebar.Figure 23. Extron W

Strany 22 - Network Screen

Updating Firmware Using GUI ConfiguratorSet up the computer and touchpanel as described in steps 1 and 2 in the previous section (Updating Firmware Usi

Strany 23 - Touch Calibration Screen

FCC Class A NoticeThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part15 of the FCC rule

Strany 24 - Software

Updating Firmware from a Web Browser1. Power on a computer that is connected to the same network as the TLP 710.2. From the Extron website (www.extr

Strany 25

Using GUI ConfiguratorThis section provides an overview of the GUI Configurator program. For complete information about the program, see the GUI Confi

Strany 26

2. Choose from the following options:• Start a New Project — Clicking OK opens a dialog box that offers a choice of project options.Figure 28. GUI C

Strany 27 - Updating the Firmware

• Download an Existing Project from a Panel — Clicking OK opens a dialog box that allows a file that has already been uploaded to a touchpanel to be d

Strany 28

3. Depending on which option was selected in step 2, GUI Configurator opens a new or existing project. The initial screen is divided into a series of

Strany 29

5. The project can be uploaded to one or more TouchLink panels. To add a panel:a. From the Project menu, select Add > Panel. The Panel Manager di

Strany 30

Using Global ConfiguratorNOTE: To configure the touchpanel, use Global Configurator version 3.3 or later.This section provides an overview of the Glo

Strany 31 - Using GUI Configurator

2. Select Create A New Project and click OK. The dialog box closes and the Project Settings dialog box opens.Figure 34. Global Configurator Project

Strany 32

4. Click OK. The Project Settings dialog box closes and is replaced by the Add Device dialog box:Figure 35. Global Configurator Add Device Dialog Bo

Strany 33

6. Click OK. The Add Device dialog box closes. The start-up screen, which was behind it, is now visible, showing the IPL 250 and the available ports:

Strany 34

Conventions Used in this GuideIn this user guide, the following are used:WARNING: A warning indicates a situation that has the potential to result in

Strany 35 - Add Panel icon (see the

9. On the Add TouchPanel dialog box, do the following:Figure 38. Add TouchPanel Dialog Boxa. Ensure the correct TouchLink panel model is selected f

Strany 36 - Using Global Configurator

MountingThis section outlines the various options for:• Rack Mounting the TLP 710MV• Wall Mounting the TLP 710MV• Furniture Mounting the TLP 710MV•

Strany 37

Wall Mounting the TLP 710MVThe following steps show how to wall-mount theTLP 710MV. Furniture-mounting is similar.1. Determine the best location for

Strany 38

Furniture Mounting the TLP 710MVThe TLP 710MV can be mounted into the surface of a lectern as follows:1. Determine the best location for the TLP 710M

Strany 39 - Click here to add one

Wall Mounting the TLP 710MV with a Wall BoxThe TLP 710MV can be wall mounted using the Extron BB 710M or the Extron EWB710M. Follow the instructions

Strany 40

Mounting with a Swivel Mount AdapterThe TLP 710TV can be mounted with the optional Extron SMA-1 swivel mount adapter. This allows the unit to be mount

Strany 41 - Mounting

VESA Mounting Holes (4)Hinges (2)Cable RunwaySpanner DriveSecurity Screws(2 for each hinge)Figure 46. Removing the Base from the Touchpanel3. If nece

Strany 42 - Wall Mounting the TLP 710MV

VESA Mounting the TLP 710TV1. Before attaching the VESA mounting kit, remove the base and back of the TLP710TV, as described in the previous section

Strany 43

Reset ModesThe TLP 710MV and TLP 710TV have four reset modes that correspond to four of the five reset modes for the IP Link controllers. The modes ar

Strany 44 - Mounting Holes (2

Extron Headquarters+1.800.633.9876 (Inside USA/Canada Only)Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +

Strany 45 - Locking Scr

ContentsIntroduction... 1About the TLP 710MV and TLP 710TV ... 1Features ...

Strany 46

TLP 710MV and TLP 710TV • Contents vi

Strany 47 - VESA Mounting the TLP 710TV

IntroductionThis guide describes the function, installation, and operation of the TouchLink TLP710MV and TLP 710 TV panels. The guide also provides i

Strany 48 - Reset Modes

RS232/RS422REMOTE1.3A MAX.100-240V , 50-60HzUSLISTEDIT23I.T.E.®L1RL2RL3RL4RL5RL6RL7RL8ROUTPUTSL1RL2RL3RL4RADDRESSINPUTSADDRESSDVI-D INPUTS56781234

Strany 49 - Extron Warranty

RequirementsComputerFor a complete list of the requirements for running GUIConfigurator or Global Configurator, see the Extron web page for that soft