Appendix B: Serial Commands VN-COMMANDER User Guide
128 I456GB issue 8
R-type Message Format
The standard R-type message structure is shown below in
both ASCII and hexadecimal formats:
ASCII text: ^A R header ^B command ^W ^C
Hexadecimal: 01 52 header 02 command 1703
The contents of the portions denoted by header’ and
command’ vary according to the required function and
can be determined from the following tables.
The spaces between characters are included for clarity
only and must not appear in the transmitted message.
Note: A full description of these commands, together with
examples, is available from Electrosonic. Please contact your
local Electrosonic representative for details.
Command
ASCII Hex
Generic R-type
Command Name
VN-COMMANDER
Function
Header
05 30 35 Goto Line / Cue Number
Selects a scene by its
position (number) in
the scene list. The first
scene is identified as 1.
Specifies the scene
number using ASCII
characters 0 to 9.
e . g .
Sc e ne 14 i s
represented by 14.
06 30 36 Goto Frame Number
Selects a scene by its
position (number) in
the scene list. The first
scene is identified as 1.
Specifies the scene
number using ASCII
characters 0 to 9.
e . g .
Sc e ne 14 i s
represented by 14.
07 30 37 Run Effect / Sub-routine
Selects a scene by its
title.
Specifies the scene
title using ASCII
characters
(see note 1).
0; 30 3B Goto Effect
Selects a scene by its
title.
Specifies the scene
title using ASCII
characters
(see note 1).
0< 30 3C Stop Current Show Stops AutoPlay.
not used