SMX System MultiMatrix Switcher • SIS Programming Guide 19
SIS Programming
Guide
The SMX uses SIS commands for operation and configuration. These
commands can be run from a PC connected to either of the SMX serial
ports or the Ethernet port. See b and d on page 3, and f on page 7
for connection information.
NOTE: The tables that begin on page 22 are a partial list of SIS
commands (see the SMX User Guide for a complete list).
This section describes selected SIS Commands and includes:
SIS Overview
SIS Command Tables
SIS Overview
Network (Ethernet) Connections
1. Open a TCP socket to port 23 using the SMX IP address
NOTE: The factory default IP address is 192.168.254.254.
The SMX responds with a copyright message including the date,
the name of the product, firmware version, part number, and the
current date and time.
2. If the SMX is not password-protected, the device is now ready to
accept SIS commands.
If the SMX is password-protected, enter the appropriate password.
If accepted, the SMX responds with Login User or Login
Administrator. If the password is not accepted, the Password
prompt reappears.
Connection time-outs
The Ethernet link disconnects after a designated period of no
communications. By default, this time-out value is set to 5 minutes
but the value can be changed.
NOTE: Extron recommends leaving the default time-out at 5
minutes and periodically issuing the Query (Q) command
to keep the connection active or disconnecting the socket
and reopening the connection when necessary.